In some mature homes you may beneficial electrical outlets with particular two prongs instead of the daily three-prong outlets seen nowadays. These two-prong outlets close not corner a ground wire. Provided you Stare at the electrical wiring in the Issue box, you Testament bonanza lone the jet and white wires which are the blistering and impartial wires. A effortless and characteristic set for this is to exchange the Issue with a GFCI (Ground Misconception Order Interrupter) Issue which is designed to interrupt the line provided there is a ground flaw. This meaning particular works for Accoutrement that does not demand a ground. Provided the Accoutrement requires a ground, the Issue must be rewired all the plan back to the main power panel.
Instructions
1. Shut off function at the leading authority panel. Bias the means for the distinct electrical wire. The wire Testament acquire to either gallop wound up the Garret, crawl margin or washed-up the basement. Provided the Garret is only used for storage, the wire can be laid across the floor of the attic. In crawl spaces and basements, the wire must be attached to the bottom of the floor joists every 4 feet for support.
Tighten the outlet box screw until the outlet box is secure. Strip 1/2 inch of insulation off the ends of the ROMEX® wire. Connect the bare ground wire to the ground terminal of the outlet. Remove the outlet box by cutting along the side of the outlet box with a reciprocating saw. Pull the old box out and pull the new wire through the hole in the wall.
3. Push the new wire into the new outlet box and push the new outlet box into the hole in the wall.2. Go to the outlet location and remove the outlet cover and outlet from the outlet box. Depending on the size and type of the new outlet, it may be necessary to replace the outlet box. Then connect the black wire to the bronze screw and the white wire to the silver screw. Tighten all screws and reinstall the outlet into the outlet box and secure the outlet cover.
4. Go to the main power panel and remove the power panel breaker cover. Locate the breaker for the outlet you have been working on. Pull out that breaker and remove the black wire attached to it. Follow that black wire back to the wires going into the house to fine the old white wire also. Cut off both of these wires and remove them from the power panel.
5. Pull the other end of the new ROMEX® wire into the power panel. Strip 1/2- nch of wire off the ends of the black and white wires. Attach the ground and white wires to the neutral bar on the left or right side of the power panel. Attach the black wire to the circuit breaker and plug it back into the power panel. Reinstall the power panel cover and then turn the power back on at the power panel.